IonX Portable Electrodes
IonX Portable Electrodes are in a “ready-to-use” state upon completion of the manufacturing process and their electrode potentials are measured at the factory, prior to shipping. A certificate of calibration is issued for each electrode.
All of the electrode types in the IonX Series utilize a unique non-porous, ionically conducting plug.
The “active” (half-cell) solution in an IonX Portable Electrode (saturated copper sulfate solution) is contained in a sealed unit that incorporates a non-porous, ionically-conducting plug.
Model | Max Diameter | Length | Weight |
---|---|---|---|
RE-5 | 1.375 in. | 6.5 in. | 0.4 lb. |
RE-5C | 1.375 in. | 7 in. | 0.44 lb. |
Measurements are approximate |
Package Contents
Certifications
IonX Portable Electrodes are in a “ready-to-use” state upon completion of the manufacturing process and their electrode potentials are measured at the factory, prior to shipping. A certificate of calibration is issued for each electrode which, in addition to indicating the electrode potential as measured at the factory, presents the certification date and the expiration date, which is 12 months beyond the date of certification. IonX Portable Electrodes can be returned annually to the factory for a calibration “check-up”.
Features & Benefits
Calibration “Check-up” Service
As is the case for other equipment items, such as voltmeters, for which annual calibration checking is suggested, M. C. Miller offers a calibration check-up service for IonX Portable Reference Electrodes (Cat. #14698).
This service includes a new 12 month certificate of calibration. An electrode will only be issued a calibration certificate if its electrode potential falls in the range 316mV +/- 10mV, versus the Standard Hydrogen Electrode (SHE). Should the external ceramic plug require replacement in order to bring an electrode into calibration, the customer would be informed and the cost of a replacement plug would be added to the service cost.
Reference Electrode | IonX RE-5, IonX RE-5C |
---|
Reference Electrode | IonX RE-5, IonX RE-5C |
---|
1550 Cobb Industrial Dr. | P.O. Box 9098 | Marietta, GA 30065-2098
770-425-1355 (Phone) | 770-425-1354 (Fax) | info@alliedcorrosion.com (Email)
Made with ❤ by Mighty Good Marketing
We care about your privacy! In order to run a successful website, we are setting cookies and accessing and storing information on your device for various purposes. By continuing to browse this site, you are agreeing to our use of cookies.
If you wish to disable cookies, please visit our Privacy Policy for more information.
Got It! Thanks!Privacy policy