Precision clock-timing even with an intermittent view of the GPS satellites.
45 Amp Model: Cat. # 12955
100 Amp Control Model: Cat. # 12950
100 Amp Relay: Cat. # 12965
When multiple current interrupters are employed on a pipeline, their internal clocks must be synchronized in order to guarantee “in-phase” current switching so that accurate instant-off potentials can be recorded.
With “non-GPS” current-interrupter units, in order to achieve (initial) clock synchronization, all participating units have to be brought together in one place. Furthermore, because of clock-drift due to local temperature variations and other effects, the clocks in the participating units can quite quickly drift out of synchronization, which leads to “out-of-phase” current waveforms.
The ideal scenario is one in which current-interrupter units can be left in the field for indefinite periods of time (with no external power source required) and their internal clocks will always be synchronized with each other during critical time periods, such as periods of repetitive current interruption (current cycling periods).
Our GPS Current-Interrupter (the Cronos unit) satisfies both of these “ideal-case” requirements.
The Cronos unit does not require an external power supply and it can run applications for years at a time using an internal battery power source. This is possible due to the advanced design of the Cronos unit which results in extremely-low power consumption, even when the unit is tracking GPS satellites.
100 Amps at 120V (12,000 watts) external relay
40 Amps at 120V (4,800 watts) internal relay
170V DC (either polarity), 120Vrms (50/60Hz).
1mV per Amp Suitable for interrupting low Voltage bonds and anodes.
75kW(10/100?s); 500kW(8/20?s) 1.2kA peak @ clamp voltage. Auto thermal shutdown at 105°C.
2,000 Volts
UTC (default) or GPS; Synchronization @ 00.00 (default) or @ start time; Local–Offset; user defined to ensure consistency
-40°C to +85°C.
Cronos PC software allows personal settings to be created and saved for future download to Cronos units, or a “master” Cronos unit can be used to automatically program other Cronos units.
Model | 45 Amp Model, 100 Amp Control Model, 100 Amp Relay Model |
---|
Model | 45 Amp Model, 100 Amp Control Model, 100 Amp Relay Model |
---|
1550 Cobb Industrial Dr. | P.O. Box 9098 | Marietta, GA 30065-2098
770-425-1355 (Phone) | 770-425-1354 (Fax) | info@alliedcorrosion.com (Email)
Made with ❤ by Mighty Good Marketing
We care about your privacy! In order to run a successful website, we are setting cookies and accessing and storing information on your device for various purposes. By continuing to browse this site, you are agreeing to our use of cookies.
If you wish to disable cookies, please visit our Privacy Policy for more information.
Got It! Thanks!Privacy policy