1550 Cobb Industrial Dr. | P.O. Box 9098 | Marietta, GA 30065-2098
770-425-1355 (Phone) | 770-425-1354 (Fax) | info@alliedcorrosion.com (Email)
©2018 Allied Corrosion. All rights Reserved.
Made with ❤ by Mighty Good Marketing
Selected:
Other than third party damage, crack growth is the most common type of polyethylene pipe failure. Shear installations and excessive bending due to external pessure are two potential causes of pipe failure.
Inadequate Support and/or protection wherever a PE pipe is inserted into an old steel or cast iron pipe, can over time develop point loading contact precisely where the plastic pipe enters and exits the metal main. Downward pressure from soil compaction may cause PE to cold flow and gradually develop a shear crack failure.
It has always been standard practice to protect inserted polyethylene services with a plastic split sleeve prior to backfilling. This type of precaution for the larger plastic mains will contribute to the long term integrity of the system. Glas Mesh FRP Type # 240 Shields and Type # 180 Saddles provide a superior means and material for protecting PE pipe at any insertion.
1550 Cobb Industrial Dr. | P.O. Box 9098 | Marietta, GA 30065-2098
770-425-1355 (Phone) | 770-425-1354 (Fax) | info@alliedcorrosion.com (Email)
Made with ❤ by Mighty Good Marketing
We care about your privacy! In order to run a successful website, we are setting cookies and accessing and storing information on your device for various purposes. By continuing to browse this site, you are agreeing to our use of cookies.
If you wish to disable cookies, please visit our Privacy Policy for more information.
Got It! Thanks!Privacy policy