A unique formulation of polymers is used in the manufacture of the Hi-Temp spacers giving them the ability to be used for applications that may reach 266° F. (130° C.).
A unique formulation of polymers is used in the manufacture of the Hi-Temp isolators/spacers giving them the ability to be used for applications that may reach 266°F. (130°C). In addition to heat resistance, they also offer excellent insulation, high abrasion resistance and low coefficient of friction for a wide variety of double containment carrier/casing pipe applications. Light in weight and easy to handle during installation, Model HT casing isolators also feature ribbed inner surface that prevents slippage and guards against carrier pipe coating damage. The outer surface may include any one of several molded runners to accommodate 2″ (50.8mm) x 4″ (101.6mm) or larger carrier/casing differentials. One piece solid molded segments provide for maximum load bearing. Hardware includes cadmium plated steel studs, nuts and washers. A screwdriver is the only tool needed for installation.
Model HT Casing Isolators are designed primarily for smaller diameter steel or polyethylene carrier pipes (ANSI O.D. pipe without a bell or mechanical joint). We do not recommend that they be used on any carrier pipe over 12″ in diameter or for installations over 300 feet long without consulting with PSI. PE Isolators should not be used on concrete carrier pipe.
Distance between all model HT Isolators/Spacers should not exceed 5 ft.(1.5m) to 8 ft.(2.4m) center-to-center. An isolator/Spacer should be placed within 2 ft. (0.6m) on each side of a coupling or joint and within 1 ft. (0.3m) of each end of the casing.
SPECIFICATION | ASTM TEST | VALUE |
---|---|---|
Material | Injection Molded Virgin Polyethylene | |
Tensile Strength |
D790 | 8,100 – 9,000 psi |
Compressive Strength |
D695 | 12,500 psi |
Water Absorption |
D570 | 0.1% |
Temperature | 266°F. Max. (130°C.) | |
Impact Strength |
D256 | 1.5 – 2.0 ft.lb/in. (0.8 – 1.07 newton meter/cm) |
Dielectric Strength |
D149 | 425 Volts/Mil. |
Color | Black |
Liner – none
Runners
3/4″ (19mm) through 12″ (305mm) = 2-piece with molded-in runners.
Hardware
Metallic – Bolts and Square Nuts are plated steel
Non-Metallic – Bolts and Nuts are high temperature plastic
Thickness | 0.118″ (3.0mm) |
Hardness | Shore “A” 73 |
Dielectric Strength 1/8″ (3.18mm) Surge Test Step-by-Step Test |
60,000 V Min. 58,000 V Min. |
Water Absorbtion | 1% Max. |
Model Size | Band Width | Runner Height |
---|---|---|
3/4 × 2 | 3.0″ (76.19mm) | 5/16 (7.94mm) |
1 × 3 | 3.0″ (76.19mm) | 1/2″ (12.7mm) |
1 1/4 × 3 | 3.0″ (76.19mm) | 1/2″ (12.7mm) |
1 1/2 × 3 | 3.0″ (76.19mm) | 1/2″ (12.7mm) |
2 × 4 | 4.0″ (101.6mm) | 5/8″ (15.88mm) |
3 × 6 | 4.0″ (101.6mm) | 5/8″ (15.88mm) |
4 × 8 | 4.0″ (101.6mm) | 1″ (25.4mm) |
6 × 10* | 4.0″ (101.6mm) | 1″ (25.4mm) |
8 × 12* | 5.0″ (127.0mm) | 1″(25.4mm) |
10 × 14* | 5.0″ (127.0mm) | 7/8″ (22.23mm) |
12 × 16* | 5.0″ (127.0mm) | 7/8″ (22.23mm) |
* Sold with liner Model HT sized for nominal steel and IPS pipe. |
For Hi-Temp Applications over 12″ Nominal O.D. use metallic casing spacers with T. P. E. Liner.
Manufacturer’s warranty statement will be supplied upon request to Allied Corrosion Industries, Inc.
To order Coated Casing Isolators please indicate the following:
Model HT Casing Isolators are designed primarily for smaller diameter steel or polyethylene carrier pipes (ANSI O.D. pipe without a bell or mechanical joint). We do not recommend that they be used on any carrier pipe over 12″ in diameter or for installations over 300 feet long without consulting with PSI. HT Isolators should not be used on concrete carrier pipe.
NOTES:
Size (Nominal ANSI) |
Specification Data |
Approximate Shipping Data |
||||
---|---|---|---|---|---|---|
Carrier | Minimum Casing |
Effective Skid Height |
Number Of Segments Per Unit |
Number Of Units Per Case |
Per Unit Weights In Pounds |
Per Case Cu. Ft. |
3/4″ | 2″ | 5/16″ | 2 | 10 | .05 | .09 |
1″ | 3″ | 1/2″ | 2 | 10 | .15 | .13 |
1-1/4″ | 3″ | 1/2″ | 2 | 10 | .20 | .14 |
1-1/2″ | 3″ | 1/2″ | 2 | 10 | .20 | .18 |
2″ | 4″ | 5/8″ | 2 | 10 | .50 | .34 |
2-1/2″ | 5″ | 5/8″ | 2 | 10 | .57 | .51 |
3″ | 6″ | 5/8″ | 2 | 10 | .65 | .47 |
4″ | 6″ | 9/16″ | 2 | 10 | .77 | .34 |
4″ | 8″ | 1″ | 2 | 10 | 1.00 | .47 |
6″ | 8″ | 9/16″ | 2 | 10 | 1.10 | .74 |
6″ | 10″ | 1″ | 2 | 10 | 1.65 | .91 |
6″(S) | 10″ | 9/16″ | 2 | 10 | 1.92 | .91 |
8″ | 10″ | 9/16″ | 2 | 10 | 1.45 | .56 |
8″ | 12″ | 1″ | 2 | 10 | 2.20 | 1.13 |
8″ (S) | 12″ | 7/8″ | 2 | 10 | 2.29 | 1.13 |
10″ | 14″ | 7/8″ | 2 | 10 | 2.37 | 1.35 |
10″ (S) | 16″ | 7/8″ | 2 | 10 | 2.55 | 1.35 |
12″ | 16″ | 7/8″ | 2 | 10 | 2.72 | 1.67 |
(S) means Somastic coated pipe |
Casing isolators/spacers shall be PSI Model HT molded from Polycarbonate plastic in two segments. Each spacer segment shall be a solid, non-welded molded piece designed for accommodating specific size pipe O.D.’s.
Each casing spacer shall be manufactured at a facility that has a Registered ISO 9001:2008 Quality Management System. Copy of current ISO 9001:2008 registration shall be provided with material submittal.
Approved manufacturer: Pipeline Seal and Insulator, Inc. For 3/4″ (19mm) through 12″ (305mm) nominal diameter carrier pipe use 2-piece model HT.
After insertion of the carrier pipe in the casing, the ends of the casing shall be closed by installing a PSI Model “C”, Model “S” or Model “FW” casing end seal as manufactured by Pipeline Seal and Insulator, Inc., Houston, TX.
(Carrier Pipe Must Centered Within Casing)
After insertion of the carrier pipe in the casing, the ends of the casing shall be closed by installing the Link-Seal® end seals and a 1/8″ thick synthetic rubber end seal equal to the PSI Model “C” end seal. Both as manufactured by Pipeline Seal and Insulator, Inc., Houston, TX.
The foregoing performance data is intended as guideline material only and is based on assumptions of general and reasonable use. Performance suitability for any specific application should be determined by the user.
Casing Spacer and End SealsEngineering Manual and Buyers Guide
1550 Cobb Industrial Dr. | P.O. Box 9098 | Marietta, GA 30065-2098
770-425-1355 (Phone) | 770-425-1354 (Fax) | info@alliedcorrosion.com (Email)
Made with ❤ by Mighty Good Marketing
We care about your privacy! In order to run a successful website, we are setting cookies and accessing and storing information on your device for various purposes. By continuing to browse this site, you are agreeing to our use of cookies.
If you wish to disable cookies, please visit our Privacy Policy for more information.
Got It! Thanks!Privacy policy