Reference Electrodes for Process Vessels

Power & Process Plant Products
Process vessel reference electrodes, through wall reference electrodes and tubesheet mounted electrodes designed and built to withstand the demanding conditions found in the power and process industries.

Reference Electrodes for Process Vessels from EDI

Process Vessel Reference Electrode

Description

The Model FE Process Vessel Reference Electrode is designed to operate in environments where ordinary reference electrodes cannot survive. These include elevated temperatures, high pressures and/or contaminated electrolytes. This is a two-piece unit consisting of a bridge which is permanently installed at each location where potential readings are desired and a separate reference electrode. Because the reference electrode is a separate piece, it is isolated it from the aggressive environment which substantially increases its service life. The reference electrode can also be removed for calibration or service without affecting the integrity of the vessel.

The Model FE10 bridge has a 316L stainless steel nipple which threads into a 1 in. NPT hole. Variations of this design have been developed which thread into a 3/4 inch NPT (Model FE7) or a 1/2 inch NPT (Model FE5) tapped hole; all three variations have a 1 inch NPT thread on the termination end. Other nipple alloys are available on special order. Bridges can be ordered with a protrusion ranging from 1 inch (2.5 cm) up to 19 inches (48 cm). Ratings on the bridge are 150 psi (1.05 MPa) and 210?F (98?C).

For intermittent readings, the reference electrode is simply pressed into the bridge. In this case, a single reference can be used with several bridges. When continuous readings are required, the reference electrode is threaded into the bridge. Reference elements available with this product are gelled copper/copper sulfate or gelled silver/silver chloride.

For More Information

Complete Product Information and Installation Instructions are available for downloading as pdf files. Click on the link below to download.
Process Vessel Reference Electrode (Model FE ) data sheet.

Reference Electrodes for Process Vessels

Reference Electrodes for Process Vessels

Learn About Our Services

Learn about our

pipeline integrity

Services

Learn about our

cathodic protection

Engineering Services

Learn about our

A/C Mitigation

Engineering Services

Learn about our

field services

Learn about our

surveying services