Universal Rectifier Air Cooled UT & SW Series

Universal Rectifier Air Cooled UT & SW Series

Pole mountable, air cooled cathodic protection rectifiers with swing out and removable case for superior accessibility for routine maintenance & inspection.

Quick Facts:

  • Simplified Rectifier Design
  • Limited to 1,600 watts DC output
  • Weather proof up to NEMA 3R
  • Stainless Steel construction with galvanized cabinet

Applications:

  • Most cathodic protection cases
  • Uses with need for routine maintenance and inspection

Universal Rectifier Type UT Rectifier Universal Rectifier Type SW Rectifier

Universal Rectifier UT & SW Series Advantages

The UT & SW Series air cooled cathodic protection rectifiers, are an alternative to Standard Line series air cooled cathodic protection rectifiers. The UT is the smallest model of the two series with a maximum of 400 watts, with all the same features as the larger SW series. Both Series rectifiers feature swing out and removable design case, which permits superior accessibility for routine maintenance and inspection. Limited to 1,600 watts of DC output, the simplified rectifier design reduces manufacturing costs and provides an economical rectifier suited for most cathodic protection applications.

Universal Rectifier UT & SW Series Features

  • Weatherproof to NEMA 3R Heavy duty
  • 11-gauge hot dip galvanized cabinet with Stainless Steel Hardware
  • Stainless Steel, perforated screens
  • Components mounted on galvanized plate for easy removal
  • Heavy duty, draw-pull, stainless steel cabinet latch
  • Heavy duty transformer with 15% over-design for reserve capacity
  • Minimum 18-step voltage control taps
  • 3/16″ Grade XX, Phenolic front panel
  • Accessible front panel Total precision shunt
  • Magnetic AC Input circuit breaker
  • Magnetic AC Secondary Breakers (instead of fuses
  • Hoyt, separate analog, 2-1/2″ round, volt and amp meters
  • Silicon diodes protected by surge suppressors and current limiting breakers
  • All electrical connection hardware is Nickel Plated and double-nutted or soldered
  • Multi-strand, high temperature, insulated flexible wiring
  • Terminal block for AC input wires
  • Safety shield panel supplied on all units over 65 Volts DC

Universal Rectifier Air Cooled UT & SW Series Optional Features

Universal Rectifier Type UT Rectifier Universal Rectifier Type SW Rectifier

Optional Features

  • A variety of AC voltage inputs single phase only
  • AC and/or DC High Energy lightning protection
  • Efficiency filter chokes
  • Communication filters
  • Meter switches
  • Power-on indicator light
  • DC circuit breakers
  • 115 VAC convenience outlet
  • Powder coated cabinet finishes (White or Gray Standard)
  • Additional voltage control adjustments
  • Other options per request of customer

Universal Rectifier Air Cooled UT & SW Series Wattage & Weight

 

Cabinet Wattages & Weights
Air Cooled UT & SW Series
Maximum
DC Watts
Shipping
Weight
lbs.
C
a
s
eS
i
z
e
UT 400 80
SW1 800 110
SW2 1200 150
SW3 1600 200
Each rectifier is custom built and will vary in weight:
The weights above are approximate.

 

Universal Rectifier Air Cooled Gas Station Series Typical Dimensions

Universal Rectifier Ut & SW Series Drawing

Typical Cabinet Dimensions
Air Cooled UT & SW Series
Letters Reference the Drawing
A B C D E F G
C
a
s
eS
i
z
e
UT 8.75 12 19 17 11 16 20
SW1 12 15 22 18.5 12 20 25
SW2 14 17 25 22 14.5 22 28
SW3 14 20 28 25.5 14.5 25 31
Case Dimensions are in inches.

 

Universal Rectifier Air Cooled UT & SW Series Ordering Code/ Model Number

  1. Position #1: MODEL
    • S = SW Series Air Cooled Rectifier
    • U = UT Series Air Cooled Rectifier
  2. Position #2: TYPE
    • S = Standard Rectifier (Manual Taps)
    • V = Variac Control
  3. Position #3: COOLING
    • A = Air Cooled
  4. Position #4: STACK TYPE
    • I = Silicon (Recommended)
    • E = Selenium
  5. Position #5: DC VOLTS
    • List Maximum DC Voltage Desired
  6. Position #6: DC AMPS
    • List Maximum DC Amperage Desired
  7. Position #7: AC INPUT
    • AA = 115/230, 1 phase set for 115 vac
    • AB = 115/230, 1 phase set for 230 vac
    • BA = 230/460, 1 phase set for 230 vac
    • BB = 230/460, 1 phase set for 460 vac
    • EA = 115/460, 1 phase set for 115 vac
    • EB = 115/460, 1 phase set for 460
    • G = 115, 1 phase only
    • H = 230, 1 phase only
    • D = 208, 3 phase
    • F = Specify
  8. Position #8: SPECIAL FEATURES
    • C = AC and DC arrestors
    • D = DC arrestor
    • E = AC arrestor
    • F = Filter Choke
    • G = Communications Filter
    • M = DC Breaker (> 100 amps) or Fuse
    • R = 115 VAC Convenience Outlet
    • N = Powder Coated Cabinet (hot-dip galvanized standard on most models)
    • P = Additional Voltage Control Link Bar Taps
    • Q = Other, Specify

Universal Rectifier Air Cooled UT & SW Series

Universal Rectifier Air Cooled UT & SW Series

Learn About Our Services

Learn about our

pipeline integrity

Services

Learn about our

cathodic protection

Engineering Services

Learn about our

A/C Mitigation

Engineering Services

Learn about our

field services

Learn about our

surveying services